Tripp Lite by Eaton

Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer, C20 Inlet, 8 C13 Outlets IS1800HGDV

UPC:
037332200037
MPN:
IS1800HGDV
Shipping:
Calculated at Checkout
  • Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer, C20 Inlet, 8 C13 Outlets IS1800HGDV
  • Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer, C20 Inlet, 8 C13 Outlets IS1800HGDV
  • Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer, C20 Inlet, 8 C13 Outlets IS1800HGDV
  • Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer, C20 Inlet, 8 C13 Outlets IS1800HGDV
  • Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer, C20 Inlet, 8 C13 Outlets IS1800HGDV
  • Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer, C20 Inlet, 8 C13 Outlets IS1800HGDV
MSRP: $2,063.36
$1,437.34
— You save $626.02

Out of stock

Description

The IS1800HGDV Isolator® Series Dual-Voltage 115/230V 1800W 50/60Hz Medical-Grade™ Transformer with full CAN/ES/IEC/EN 60601-1 listing is ideal for protecting sensitive electronic equipment in patient-care vicinities. It can be configured for either step-up voltage, step-down voltage or pass-through voltage operation. Along with line isolation and continuous EMI/RFI line noise filtering, its surge protection rating of 240 joules suppresses excess voltage to prevent it from damaging connected equipment.

An internal low-impedance isolation transformer component offers 100% isolation from the input mains AC line. Faraday shield reduces the cumulative leakage current of the IS1800HGDV and connected equipment to levels less than 100 microamps, while removing utility switching transients and harmonics generated by other on-site loads and reducing the impact of utility or lightning related surge conditions.

Transformer filtering provides continuous common-mode noise rejection with no wearable parts. The IS1800HGDV reduces 6000V IEEE 587 Category A and B ring wave and combination wave test surges to only 0.5V common mode.

Components connect to eight C13 outlets with fuse overload protection and a lighted on/off switch. The rugged all-metal unit housing ships ready for placement in any industrial, medical, office, network or audio/video environment. Requires a C20-to-C19 AC input cord (sold separately).
  • Ideal for use in any industrial, network or medical environment
  • Offers complete isolation from input AC mains power
  • Automatically shuts down all outlets in case of overload
  • Cumulative leakage current less than 100 µA
  • Protects sensitive equipment from EMI/RFI line noise and surges
View AllClose

Additional Information

Power Rating:
1800 VA
Environmentally Friendly:
Yes
Input Voltage:
120 V AC,230 V AC
Input Receptacle Type:
IEC 60320 C14
Limited Warranty:
2 Year
Maximum Line Current:
15 A
Form Factor:
Cabinet
Package Contents:
  • Isolator IS1800HGDV Isolation Transformer
  • 2 x Fuse Sets (115V and 230V Operation)
  • Input/Output Cable Selector Data Sheet
  • Owner's Manual
Manufacturer Website Address:
https://tripplite.eaton.com/
Output Receptacle Type:
IEC 60320 C13
Product Type:
Isolation Transformer
Manufacturer:
Tripp Lite by Eaton
Product Model:
IS1800HGDV
Output Voltage:
115 V AC,230 V AC
Country of Origin:
China
Product Line:
Isolator